LED Status Description
PWR OFF No internal power
ON Internal Power OK
TD OFF No serial data transmitted from the unit,
(RS-232 or RS-422/485)
ON Serial data transmitted from the unit, (RS-232 or RS-422/485)
RD OFF No serial data received to the unit, (RS-232 or RS-422/485)
ON Serial data received to the unit, (RS-232 or RS-422/485)
RTS OFF No RTS to the RS-232 interface or RS-422/485 transmitting.
ON RTS to the RS-232 interface or RS-422/485 receiving.
CTS OFF No CTS from the RS-232 interface
ON CTS from the RS-232 interface
LINK OFF No Ethernet link.
Cable not connected.
ON Good Ethernet link.
Flash Ethernet data is transmitted or received, traffic indication.
STAT OFF Normally Off
ON Telnet session established to Telnet diagnostics service or
Ongoing configuration by Web tool
RC OFF DIP switch settings are valid.
ON One or more DIP switches are overrid by remote configuration
SPD ON Ethernet 100 Mbit/s
OFF Ethernet 10 Mbit/s
DPX ON Full duplex
OFF Half duplex
22
6616-2202
LED Indicators
Power
Transmit data
Receive data
Request to send
Clear to send
Status
Remotely controlled
Speed Integrated in RJ-45
Green
Duplex Integrated in RJ-45
Ye l l o w
8
7
6
5
4
3
2
1
Ethernet
Ethernet TX connection (RJ-45 connector), automatic MDI/MDI-X crossover*.
Contact Signal Name Direction Description/Remark
1 TD+ In/Out Transmitted/Received data
2 TD– In/Out Transmitted/Received data
3 RD+ In/Out Transmitted/Received data
4 NC
5 NC
6 RD– In/Out Transmitted/Received data
7 NC
8 NC
Shield HF-connected
CAT 5 cable is rec-
ommended.
Unshielded (UTP) or
shielded (STP) con-
nector might be used.
* Depend of settings on S1; 6, 7 and 8.