©Westermo Teleindustri ABwww.westermo.comSerial AdapterUser Guide 6616-2203EDW-100

Page 2 - Software tools

106616-2203IntroductionThe EDW-100 is an Industrial Ethernet to serial adapter or Ethernet Terminal Server. The serial interface is selectable between

Page 3 - Maintenance

116616-2203For more information on applications and technical data visit www.westermo.com. The Web tool also includes an integrated help where all fun

Page 4

126616-2203Product descriptionThe EDW-100 is an industrial Ethernet to serial interface adapter designed for harsh environments. It allows serial devi

Page 5 - Safety Control Drawing

136616-2203Termination and fail-safe of the RS-422/485 serial interface can only be made by DIP-switches only. The local IP address of the unit can be

Page 6

146616-2203The Telnet diagnostic service provide the user with information such as UDP- or TCP mode, connected or listening state (TCP) etc.C:\WINDOWS

Page 7

156616-2203Getting startedIP AddressThe default IP address of the EDW-100 when delivered is 169.254.100.100. Default port 9000 Default gateway 169.254

Page 8 - Declaration of conformity

166616-2203Username and Password for configurationThe EDW-100 is username and password protected. These are used when connecting with Web browser duri

Page 9

176616-2203Configuration by Web ToolThe EDW-100 includes an easy-to-use Web configuration tool. The Web tool is very intuitive and includes useful hel

Page 10 - Introduction

186616-2203Diagnostics via TelnetThe EDW-100 provides the user with diagnostics information via a Telnet connection on port 23.Information presented t

Page 11 - 6616-2203

196616-2203Short description of TCP and UDPUser Datagram Protocol (UDP)UDP provides a connectionless datagram service. This means that the arrival of

Page 12 - Product description

26616-2203Legal informationThe contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind, either

Page 13

206616-2203Short description of ModbusModbus is a communication protocol developed by Modicon systems. The EDW-100 Modbus gateway is used for intercon

Page 14 - Diagnostic information

216616-2203Gateway Client modeAllows one Modbus client (master) on a serial network to connect to one or more servers (slaves) on the TCP/IP network.S

Page 15 - Getting started

226616-2203Advanced settingsAdvanced settings configure the unit for special application requirements or special interface functions, these settings a

Page 16 - 1 2 3 4 5 6 7 8

236616-2203Interface specifications* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m bound

Page 17 - Configuration by Web Tool

246616-2203* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m boundary to the rails and con

Page 18

256616-2203LED indicators, also integrated in the RJ-45 connector. (for details see next page)S2 DIP-switch Termination (for details see page 25)

Page 19

266616-2203LED Indicators87654321EthernetEthernet TX connection (RJ-45 connector), automatic MDI/MDI-X crossover*.CAT 5 cable is recommended. Unshield

Page 20 - Short description of Modbus

276616-2203DIP-switch settingsBefore DIP-switch settings:Prevent damage to internal electronics from electrostatic discharges (ESD) by discharging you

Page 21

286616-2203CoolingThis unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules. Minimum spacin

Page 22

296616-2203Applications=TerminationEDW-100 Slave unit Slave unit Slave unitEDW-100Slave unit Slave unit Slave unitMax 0.3 metre=TerminationT+T–T+T- T+

Page 23 - Interface specifications

36616-2203SafetyBefore using this unit:Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Che

Page 24

306616-2203One to many using UDP using broadcast or multicast DescriptionThe one to many function can be used in place of a traditional RS-422 or RS

Page 25 - Connections

316616-2203Point to point using UDP connectionCommunication one to many using TCP DescriptionIn a point to point application the EDW-100 can be to re

Page 26 - Ethernet

REV. F 6616-2203 2015-01 Westermo Teleindustri AB, Sweden – A Beijer Electronics Group CompanyFor complete contact information, please visit our

Page 27 - DIP-switch settings

46616-2203GeneralThis unit is intended for use in Zone 2 hazardous location only.MarkingBaseefa 14ATEX0294X II 3 G Ex nA IIC T4 Gc IECEx BAS 14.0

Page 28 - Mounting

56616-2203RatingsPower 12 – 48 VDC; 250 mAAmbient temperature –25ºC ≤ Ta ≤ +70ºCIngress protection (IP) IP21Maximum surface temperatur 135ºC (tempe

Page 29 - 3.3 V = >1.5 V

66616-2203SPECIAL CONDITION FOR SAFE USEAmbient temperature:This unit is designed for use in extreme ambient temperature conditions as follows: –25ºC

Page 30 - Description

76616-2203Agency approvals and standards complianceType Approval / ComplianceEMCEN 50121-4, Railway signalling and telecommunications apparatusEN 5502

Page 31

86616-2203 Westermo Teleindustri AB Declaration of conformity Org.nr/ Postadress/Postal address Tel. Telefax Postgiro Bankgiro Corp. ident

Page 32 - Sales Units

96616-2203Type tests and environmental conditionsElectromagnetic CompatibilityPhenomena Test Description Test levelsESD EN 61000-4-2 Enclosure contact